LED
Description
Power input
5
• Off: The power supply is disconnected from the ac power source or a power problem occurs.
LED
• Green: The power supply is connected to the ac power source.
Power output
6
• Off: The server is powered off, or the power supply is not working properly. If the server is
LED
powered on but the output status LED is off, replace the power supply.
• Blinking green: The power supply is in the zero-output mode (standby). When the server
power load is low, one of the installed power supplies enters into the standby state while the
other one delivers the entire load. When the power load increases, the standby power supply
will switch to active state to provide sufficient power to the system.
To disable zero-output mode, start the Setup utility, go to System Settings ➙ Power ➙ Zero
Output and select Disable. If you disable the zero-out mode, both power supplies will be in
the active state.
• Green: The server is on and the power supply is working normally.
Power supply
7
• Off: The power supply is working normally
error LED
• Yellow: The power supply has failed. To resolve the issue, replace the power supply.
ThinkSystem SR550 Setup Guide
26