Reel Motor Service

1
3
2
Use seal protector tool
TOR4072 when inserting
shaft through seal.
NOTE: Seal protector tool is
part of TOR4070 Cutting Unit
Tool Kit shown in Chapter 8 -
Cutting Units.
1. Retaining Ring
2. Shaft seal
3. Flange

Removal

1. Park machine on a level surface, lower cutting units,
stop engine, engage parking brake, and remove key
from the ignition switch.
2. Disconnect hydraulic lines. Put caps or plugs on fit-
tings and hoses to prevent contamination. Tag hydraulic
lines for proper reassembly.
3. Loosen motor mounting nuts (Fig. 88).
4. Rotate motor clockwise so motor flanges clear studs
and pull motor out.

Installation

1. Place motor into position on mounting studs. Rotate
motor counterclockwise so motor flanges lock to studs.
2. Tighten motor mounting nuts
3. Remove caps or plugs from fittings and hoses. Con-
nect hydraulic lines lines to the motor.
Hydraulic System (Rev. C)
4
5
6
Figure 87
4. E-Seal
5. O-Ring
6. Dowel pin
Page 4 - 74
7. Valve Block
8. Adjusting valve
1
Figure 88
1. Reel motor
7
8
40 to 45 ft−lb
(54 to 61 N−m)
2
2. Motor mounting nut