15.Slide pump shaft and bearing assembly from hous-
ing. Press shaft out of bearing (Fig. 51).
16.Remove hex tapping screws retaining the trunnion
seal cover and trunnion cover to housing. Mark position
of covers for reassembly. The trunnion seal cover as-
sembly includes an O-ring, lip seal, and trunnion bearing
on the control side. The trunnion cover assembly in-
cludes an O-ring and trunnion bearing on the side oppo-
site the control. Remove these parts from the housing
(Fig. 52).
17.Tilt and lift swashplate from housing (Fig. 53).
Hydraulic System (Rev. C)
Page 4 - 56
Figure 51
Figure 52
Figure 53