Chapter 3.
Installing an Isolation Valve
3.1
Introduction
If one has not already been installed, follow the instructions in this chapter to install an isolation valve on each
transducer nozzle for applications using the flare gas insertion mechanism. As the procedure is identical for all path
configurations and flange sizes, only one installation configuration is described here as an example.
3.2
Valve Installation for 3-inch Flanges
Refer to Figure 66 below and install 3-inch ANSI flanged full-bore isolation valves on both transducer nozzles with a
gasket, studs and nuts. Orient the valve handles to minimize interference. Note the following requirements:
•
150# RF flanges:
•
300# RF flanges:
Model T17 Installation Guide
8 in. face-to-face distance, 5/8 in. diameter studs and nuts
11.125 in. face-to-face distance, 3/4 in. diameter studs and nuts
UPSTREAM
TRANSDUCER PORT
GASKET
FLOW
Figure 66: Standard Isolation Valve Installation
3 INCH 150 LB, RF WELDING NECK FLANGE
2 PLACES; REF ONLY
3 INCH SCH 80 PIPE NOZZLE
2 PLACES; REF ONLY
Chapter 3. Installing an Isolation Valve
GASKET
DOWNSTREAM
TRANSDUCER PORT
55