Button Settings; Setting Output Signals; Setting Multiview Displays; Setting A Tally - Panasonic AV-HS6000 Series Operation Manual

2me live switcher
Hide thumbs Also See for AV-HS6000 Series:
Table of Contents

Advertisement

[On]
[Off]

Button settings

Assigning video sources to buttons
External video input signals and internally generated signals can be assigned to the crosspoint buttons (the PGM/A, PST/B, and KEY bus crosspoint
buttons) in the crosspoint area.
f For details, refer to "Assigning signals to buttons" (page 131).
1
Select the <CONF> button → [XPT ASSIGN] → [MainPanel]/[SubPanel1]/[SubPanel2] tab, and make the following settings.
[MainPanel] tab
[SubPanel1] tab
[SubPanel2] tab
Disabling button/block operations
Operations can be disabled for each button or block.
f For details, refer to "Disabling button operations" (page 130).
1
Select the <CONF> button → [BUTTON INHIBIT] → [MainPanel]/[SubPanel1]/[SubPanel2] tab, and make the following settings.
[MainPanel] tab
[SubPanel1] tab
[SubPanel2] tab
Setting button colors
For details on the button color settings, refer to "Setting the button color" (page 151).

Setting output signals

Make various settings for SDI output signals.
f For details, refer to "Setting output signals" (page 125).
1
Select the <IN OUT> button → [SDI OUT] → [Assign]/[Down Converter] tab, and make the following settings.
[Assign] tab
[Down Converter] tab
2
Select the <IN OUT> button → [C/C OUT] → [SDI OUT 13] to [SDI OUT 16] tabs, and make the color corrector settings.
f Make the settings for color correctors built into the <SDI OUT 13> to <SDI OUT 16> terminals.
f For details on the settings output from the ME/DSK block such as ME1CLN and ME2CLN, refer to "Setting the ME output and DSK output"
(page 148).

Setting MultiView displays

If the output signal is set to MV1 to MV4, multiple images can be simultaneously displayed on a maximum of 16 split screens.
f For details, refer to "Setting MultiView displays" (page 127).
1
Select the <MV> button → [MV1‑4] → [MV1] to [MV4] tabs.
2
In the [Pattern] column, make the settings for the split pattern of the MultiView display.
f When [Assign] is selected, the source settings screen will be displayed on a sub-screen.
3
In the [MV Frame]/[Tally Box]/[Tally Label L]/[Tally Label R]/[Display] column, set the information displayed on the sub‑screen.

Setting a tally

Setting reference outputs
For details on the tally group settings, refer to "Setting a tally" (page 153).
1
Select the <SYS> button → [PERIPHERAL] → [Tally] tab.
2
Select an item in [Target A], [+Target B], [+Target C], and [+Target D] of the [Tally Group1‑1 (On‑Air)] column, and select an item in
[+Target E], [+Target F], [+Target G], and [+Target H] of the [Tally Group1‑2 (On‑Air)] column.
f Select up to eight reference outputs to be used for the on-air tally.
3
Select an item in [Target A], [+Target B], [+Target C], [+Target D] of the [Tally Group2‑1] to [Tally Group4‑1] columns, and select an
item in [+Target E], [+Target F], [+Target G], and [+Target H] of the [Tally Group2‑2] to [Tally Group4‑2] columns.
Chapter 4 Preparations — Various settings
Enables link settings.
Disables link settings.
Assigns the main control panel.
Assigns the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).
Assigns the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).
Assigns the main control panel.
Assigns the sub control panel 1 (second Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).
Assigns the sub control panel 2 (third Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4).
Assigns output matrix.
Makes the settings for down-converters built into the <SDI OUT 14>/<SDI OUT 16> terminals.
– 50 –

Advertisement

Table of Contents
loading

Table of Contents