Parameter List - Mitsubishi Electric 700 Series Instruction Manual

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Parameter list

5.2
Parameter list
5.2.1
Parameter list
For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check are available
from the operation panel. For details of parameters, refer to the instruction manual.
REMARKS
indicates simple mode parameters. (initially set to extended mode)
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection. (Note that the Pr.77 setting cannot be changed through FL remote
communication.)
Func-
Parameter
Name
tion
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
4
Multi-speed setting (high speed)
5
Multi-speed setting (middle speed)
6
Multi-speed setting (low speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
10
DC injection brake operation frequency 0 to 120Hz
11
DC injection brake operation time
12
DC injection brake operation voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
16
Jog acceleration/deceleration time
17
MRS input selection
18
High speed maximum frequency
19
Base frequency voltage
Acceleration/deceleration reference
20
frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level
Stall prevention operation level
23
compensation factor at double speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
78
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 30%
0.1%
6/4/3/2%
∗1
94
0 to 120Hz
0.01Hz
120Hz
105
0 to 120Hz
0.01Hz
0Hz
105
0 to 400Hz
0.01Hz
60Hz
107
0 to 400Hz
0.01Hz
60Hz
111
0 to 400Hz
0.01Hz
30Hz
111
0 to 400Hz
0.01Hz
10Hz
111
0 to 3600/360s
0.1/0.01s
5/10/15s
116
∗2
0 to 3600/360s
0.1/0.01s
5/10/15s
116
∗2
Rated
0 to 500A
0.01A
inverter
123
current
0.01Hz
3Hz
135
0 to 10s
0.1s
0.5s
135
0 to 30%
0.1%
6/4/2%
135
∗3
0 to 60Hz
0.01Hz
0.5Hz
119
0 to 3
1
0
109
0 to 400Hz
0.01Hz
5Hz
171
0 to 3600/360s
0.1/0.01s
0.5s
171
0, 2, 4
1
0
143
120 to 400Hz
0.01Hz
120Hz
105
0 to 1000V, 8888, 9999
0.1V
9999
107
1 to 400Hz
0.01Hz
60Hz
116
0, 1
1
0
116
0 to 200%
0.1%
150%
101
0 to 200%, 9999
0.1%
9999
101
0 to 400Hz, 9999
0.01Hz
9999
111
0 to 400Hz, 9999
0.01Hz
9999
111
0 to 400Hz, 9999
0.01Hz
9999
111
0 to 400Hz, 9999
0.01Hz
9999
111
0, 1, 2
1
0
120
" " indicates valid and "×" indicates invalid of "control mode-based correspondence table", "parameter clear", and "all parameter clear".
Control Mode-based
Customer
Correspondence Table
Parameter
Setting
V/F
V/F
V/F
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
29
Parameter
Clear
All clear
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
×
×
×
×
×
×
×
×
Parameter list
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents