Log Data Read; Log Data Clear - Mitsubishi Electric 700 Series Instruction Manual

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

4.8.4

Log data read

With this function, log information of other node is read from network.
Item
Request
Not applicable
Offset
+12 to +20
+36 to +44
Normal
response
+64, +68
Response
+88, +92
+100
+104
+108
+112
+116 to +140
+144
+148
Error
Offset
response
4.8.5

Log data clear

Clears log information (Refer to page 69) of other node from network.
Item
Request
Not applicable
Normal
Not applicable
response
Response
Error
Offset
response
Bit7 to Bit0
The number of communication socket
+0
transmitting times
The number of communication socket
+4
transmitting error times
The number of Ethernet transmitting
+8
error times
The number of communication socket
+24
receiving times
The number of communication socket
+28
receiving error times
The number of Ethernet receiving
+32
error times
The number of token transmitting
+48
times
The number of cyclic frame
+52
transmitting times
The number of 1:1 message
+56
transmitting times
The number of 1:n message
+60
transmitting times
+72
The number of token receiving times
The number of cyclic frame receiving
+76
times
The number of 1:1 message receiving
+80
times
The number of 1:n message receiving
+84
times
The number of cyclic transmission
+96
receiving error times
The number of cyclic address size
error times
The number of cyclic CBN error times
The number of cyclic TBN error times
The number of cyclic BSIZE error
times
The number of message transmission
retransmitting times
The number of message transmission
retransmitting over times
Bit15 to Bit0
+0
Error code (Refer to page 61)
Bit15 to Bit0
+0
Error code (Refer to page 61)
Message transmission
Data Portion
Offset
+152 to +164
The number of message transmission
+168
The number of message sequence
+172
The number of message sequence
+176
retransmitting recognition times
+180 to +188
+192
The number of ACK error times
The number of ACK sequence version
+196
The number of ACK sequence
+200
The number of ACK node number
+204
+208
The number of ACK TCD error times
+212 to +236
The number of token multiplexing
+240
+244
The number of token destroyed times
+248
The number of token reissued times
+252 to +260
The number of token hold time out
+264
The number of token monitoring time
+268
+272 to +284
+288
The number of frame waiting status
+292
+296
+300
The number of times disconnected
The number of disconnected times
+304
The number of recognition times of
+308
+312 to
+332
+336 to
List of participation recognized node
+364
+368 to
+508
Data Portion
Bit7 to Bit0
receiving error times
version error times
error times
number error times
error times
recognition times
times
out times
Total operation times
times
Entry time
due to skip
other node disconnected
4
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents