Option and Peripheral Devices

Option list

By fitting the following options to the drive unit, the drive unit is provided with more functions.
One type of plug-in option can be mounted.
Name
CC-Link communication
Parameter unit
Enclosure surface operation
panel
Parameter unit connection
cable
USB cable
DIN rail attachment
AC reactor
DC reactor
EMC Directive compliant
noise filter
Radio noise filter
Line noise filter
Filterpack
Brake resistor
High-duty brake resistor
Brake unit, Resistor unit,
Discharging resistor
Power regeneration common
converter
Stand-alone reactor dedicated
for the FR-CV
High power factor converter
Manual controller
DC tach. follower
Three speed selector
Motorized speed setter
Ratio setter
Speed detector
Master controller
Soft starter
Deviation detector
Preamplifier
35
Model
This option allows the drive unit to be operated or monitored or
FR-A7NC E kit
the parameter setting to be changed from a programmable
controller, etc.
FR-PU07
Interactive parameter unit with LCD display
This operation panel enables drive unit operation and monitoring
FR-PA07
of frequency, etc. from the enclosure surface
Cable for connection of operation panel or parameter unit.
FR-CB20
 indicates a cable length. (1m, 3m, or 5m)
MR-J3USBCBL3M
Connector for amplifier
mini-B connector (5 pin)
Cable length 3m
FR-UDA01
Attachment for installation on a DIN rail
FR-HAL
For harmonic current reduction and drive unit input power factor
FR-HEL
improvement
SF
EMC Directive (EN61800-3 C3) compliant noise filter
FR-BIF(H)
For radio noise reduction (connect to the input side)
FR-BSF01, FR-BLF
For line noise reduction
Combination of power factor improving DC reactor, common
FR-BFP2
mode choke, and capacitative filter
For increasing the regenerative braking capability (permissible
MRS type
duty 3%ED)
For increasing the regenerative braking capability (permissible
FR-ABR
duty 10%/6%ED)
For increasing the braking capability of the drive unit (for high-
inertia load or negative load).
FR-BU2, GZG type
Brake unit, electrical-discharge resistor and resistor unit are used
in combination.
FR-CV
Unit which can return motor-generated braking energy back to
FR-CVL
the power supply in common converter system
The high power factor converter switches the converter section
on/off to reshape an input current waveform into a sine wave,
FR-HC2
greatly suppressing harmonics. (Used in combination with the
standard accessory.)
For independent operation. With a frequency meter, a frequency
FR-AX
potentiometer and a start switch.
For synchronous operation (1VA) by external signal (0 to 5V, 0 to
FR-AL
10V DC) 
For three speed switching, among high, middle and low speed
FR-AT
operation (1.5VA) 
For remote operation. Allows operation to be controlled from
FR-FK
several places (5VA). 
For ratio operation. The ratios of five drive units can be set (3VA).
FR-FH

FR-FP
For tracking operation by a pilot generator (PG) signal (3VA)
Master controller (5VA) for parallel operation of multiple
FR-FG
(maximum 35) drive units. 
For soft start and stop. Enables acceleration/deceleration in
FR-FC
parallel operation (3VA). 
For continuous speed control operation. Used in combination with
FR-FD
a deviation sensor or synchro (5VA). 
Used as an A/V converter or arithmetic amplifier (3VA) 
FR-FA
Applications, Specifications, etc.
Connector for personal computer
A connector
Applicable
drive unit
All models
All models
Applicable to
some capacities
Applicable to
some capacities
Applicable to
some capacities
All models
All models
0.4K or higher
0.4K or higher
0.4K or higher
0.4K or higher
Applicable to
some capacities
All models