Sony ZRD-1 Service Manual page 36

Display unit
Table of Contents

Advertisement

Category
Code on DCS
Temperature/Fan
313
313
-
-
313
11
Front view
1
2
5
6
9
0
-
-
313
31
3-18 (E)
Code on CAS
313-
-21
313-
-22
-
-
14
313-
-23
3
4
7
8
!-
!=
313-
-24
-
-
313
34
313-
-31
313-
-32
313-
-33
313-
-34
Symptom/Cause/Remedy
Symptom/Cause: Temperature of the cell of 5 shown in the figure on
the left (in the middle line, and first from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 6 shown in the figure on
the left (in the middle line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 7 shown in the figure on
the left (in the middle line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 8 shown in the figure on
the left (in the middle line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 9 shown in the figure on
the left (in the bottom line, and first from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of 0 shown in the figure on
the left (in the bottom line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of !- shown in the figure on
the left (in the bottom line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
Symptom/Cause: Temperature of the cell of != shown in the figure on
the left (in the bottom line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Check the temperature of the cell. If the temperature is abnormal,
replace the specified cell.
ZRD-1/ZRD-2