Code on DCS
Temperature
113
113
-
-
113
11
Front view
1
2
5
6
9
0
-
-
113
31
ZRD-1/ZRD-2
Code on CAS
113-
-21
113-
-22
-
-
14
113-
-23
3
4
7
8
!-
!=
113-
-24
113-
-31
-
-
113
34
113-
-32
113-
-33
113-
-34
Symptom/Cause/Remedy
Symptom/Cause: Temperature of the cell of 5 shown in the figure on
the left (in the middle line, and first from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 6 shown in the figure on
the left (in the middle line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 7 shown in the figure
on the left (in the middle line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 8 shown in the figure on
the left (in the middle line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 9 shown in the figure on
the left (in the bottom line, and first from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of 0 shown in the figure on
the left (in the bottom line, and second from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of !- shown in the figure on
the left (in the bottom line, and third from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.
Symptom/Cause: Temperature of the cell of != shown in the figure on
the left (in the bottom line, and fourth from the left
viewed from the front) is abnormal.
Remedy:
. Check if the air intake hole or the fan is not blocked.
. Lower the temperature around the array.
. Replace the specified cell.