Cabinet Design and EMC
14.7 Cooling
Electronic losses of Motor Modules/Line Modules
Table 14-22 Electronic losses of Motor Modules/Line Modules
Component
Motor Modules
Active Line Modules
Smart Line Module
Basic Line Modules
344
3 A
5 A
9 A
18 A
30 A
45 A
60 A
85 A
132 A
200 A
2x3 A
2x5 A
2x9 A
2x18 A
16 kW
36 kW
55 kW
80 kW
120 kW
5 kW
10 kW
20 kW
40 kW
100 kW
Current consumption
[A]
0,6
0,6
0,6
0,6
0,6
0,7
0,7
1
1,5
1,5
0,85
0,85
0,85
0,95
0,8
1
1,4
2
2,5
0,65
0,7
0,9
1,1
1,6
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
Cold plate
Power loss
[W]
14,4
14,4
14,4
14,4
14,4
16,8
16,8
24,0
36,0
36,0
20,4
20,4
20,4
22,8
19,2
24,0
33,6
48,0
60,0
15,6
16,8
21,6
26,4
38,4