Canon imageCLASS MF4890dw Service Manual page 483

Hide thumbs Also See for imageCLASS MF4890dw:
Table of Contents

Advertisement

Code
Detection description
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Light intensity of a lamp is
E225
0001
less or equal to the criteria
(2) Replace the Flat Cable between Main Controller
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of Flat Cable between Main
Insufficient light intensity in
E301
0001
shading
(2) Replace the Flat Cable between Main Controller
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
following remedies.
(1) Check the connection of connectors between the
Communication error with
CCU/modem, or no FAX
E736
0000
board installed on FAX
(2) Replace the connectors between the Main Controller
model.
(3) Replace the FAX-NCU Board.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
Error detection on either
times of turning the power OFF/ON, execute the
E740
0002
Network Board or Mac
following remedies.
address
(1) Check the connection of the network cable.
(2) Replace the Main Controller Board.
7
Error Codes > Error Codes
Remedy
Controller Board (J5) and Contact Sensor.
Board (J5) and Contact Sensor.
Controller Board (J5) and Contact Sensor.
Board (J5) and Contact Sensor.
Main Controller Board (J601, J602) and the FAX-
NCU Board (J1201, J1204).
Board (J601, J602) and the FAX-NCU Board (J1201,
J1204).
7
Error Codes > Error Codes
Code
Detection description
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
0002 Language file error
following remedies.
Update the set of the Controller Firmware
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
Engine ID error (Invalid
following remedies.
4000
engine connection is
E744
(1) Check the Engine Controller Board.
detected)
(2) Update the Engine Firmware.
(3) Update the set of the Controller Firmware
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
Communication error with
6000
following remedies.
Wireless LAN board.
(1) Replace the Wireless LAN Board.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the
Fan Motor cannot rotate at
E806
0000
following remedies.
specified revolution speed.
(1) Replace the Main Fan Unit.
(2) Replace the Engine Controller Board.
7-4
Remedy
T-7-2
7-4

Advertisement

Table of Contents
loading

Table of Contents