Canon imageCLASS MF4890dw Service Manual page 398

Hide thumbs Also See for imageCLASS MF4890dw:
Table of Contents

Advertisement

4
Disassembly/Assembly > Pickup And Feeding System > Removing the Duplex Solenoid (MF4890dw/MF4880dw) > Procedure
Caution:
When mounting the scanner cover, pass the shutter open/close lever [1] through the
hole [A] in the scanner cover.
Caution:
Ensure that the shutter open/close lever [1] can move vertically.
4
Disassembly/Assembly > Pickup And Feeding System > Removing the Duplex Solenoid (MF4890dw/MF4880dw) > Procedure
[A]
[1]
F-4-891
[1]
F-4-892
2)Free the solenoid harness[1] from the guide[A], and put it through the hole[B] of the right
side plate to the outside.
3)Remove the duplex solenoid[1].
[1]
4-322
[2]
[1]
[A]
[B]
F-4-893
[2]
F-4-894
4-322