Storing During Maintenance; Installation; Unpacking - Bosch Rexroth Hägglunds CA Series Installation And Maintenance Manual

Radial piston hydraulic motor
Hide thumbs Also See for Rexroth Hägglunds CA Series:
Table of Contents

Advertisement

20/52

Installation

RE 15354-WA/04.2015, Installation and maintenance manual, Hägglunds CA 10 - CA 40, Bosch Rexroth Mellansel AB

6.2.3 Storing during maintenance

If the motor has been used (thus the initial rust protection has been diluted/flushed)
it can be stored up to one month, without additional rust protection. After one
month it must be protected from internal rust. This can be done as follows:
• Mix anti-rust additive with the hydraulic fluid of the system. Use 2% of Shell VSI
8235, or similar compatible to the selected fluid. This additive gives rust protection
for up to about 3 month in uncontrolled environment or 12 months in controlled
environment.
• If no additives are used, the motor must be turned a few revolutions once a month
to maintain an oil film.
• If it is not possible to turn the motor, or the storage is longer than stated periods
above, the motor must be filled according to chapter 6.2.2: Storing for extended
periods or in uncontrolled environment.
If the motor is kept mounted on the driven shaft, any air should be bled off through
D1-D2 for vertical shaft mount, before shut down.
7
Installation

7.1 Unpacking

Danger from parts falling out!
If the packaging is not opened correctly, parts may fall out and damage the parts or
even cause injuries!
1 Place the packaging on a flat and solid surface.
2 Only open the packaging from the top.
3 Remove the packaging from the Hägglunds motor.
4 Check the Hägglunds motor for transport damage and completeness, see
chapter 4: Delivery contents.
5 Dispose of the packaging according to the environmental regulations of your
country.
CAUTION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents