Installation | Hägglunds CA Radial piston hydraulic motor
6.2.3
Storing during maintenance
If the motor has been in operation and the oil in the hydraulic system fulfills the
requirements in
data sheet RE 15414,
can be stored for one month without additional rust protection.
The oil connections of the motor must be properly plugged/covered during the
whole storage period to avoid any contamination or humidity/water to enter the
motor.
If the storage time is longer than one month, follow the instructions in 6.2.2, or
if the motor is kept on the shaft, the power unit must be started and the motor
rotated once a month.
7 Installation
7.1
UNPACKING
Danger from parts falling out
If the packaging is not opened correctly, parts may fall out and damage the parts
or even cause injuries.
▶ Place the packaging on a flat and solid surface.
▶ Only open the packaging from the top.
▶ Remove the packaging from the Hägglunds motor.
▶ Check the Hägglunds motor for transport damage and completeness, see
chapter 4: Scope of delivery.
▶ Dispose of the packaging according to the environmental regulations of your
country.
regarding water content, the drained motor
CAUTION
RE 15305-WA, Version 11.2019, Bosch Rexroth AB