Bosch Rexroth Mellansel AB, Installation and maintenance manual, Hägglunds CA 10 - CA 40, RE 15354-WA/04.2015

6.2.2 Storing for extended periods or in uncontrolled environment

Insufficient cleanliness!
Risk of damage to equipment.
Take extreme care to ensure that no contamination enters the motor.
If the motor is stored for more than 3 months in an uncontrolled environment or
more than 12 months in a controlled environment, it must be filled with oil.
1 Place the motor as shown in Fig. 7: Hägglunds CA 10 - CA 40 standing on a flat
surface, alt.A) Standing with shaft horizontal.
2 Fill the motor with filtered oil in the following order: D1, A1, C1.
NOTE! See Table 5: Oil volume.
3 Seal connections A1 and C1 with the plugs fitted to the connection surface at
delivery. Check that the O-rings or rubber seals are in position on the plugs.
4 Fit the plug to D1.
5 Position the motor as shown in Fig. 7: Hägglunds CA 10 - CA 40 standing on a flat
surface, alt. A) Standing with shaft horizontal. or B) Standing with shaft vertical.
Table 5: Oil volume
Motor
Oil volume approx.
litres
CA 10
0.7
CA 20
1.0
CA 30
1.1
CA 40
1.2
Fig. 8: Filling the motor with oil