Parameter assignment
3.3 PROFIBUS DP parameter assignment
3.3
PROFIBUS DP parameter assignment
3.3.1
Parameter assignment sequence
Parameter assignment sequence
The PROFIBUS DP parameter assignment for the ADI4 DP slave can be generally divided
into the following steps:
1. Step
2. Step
3.3.2
Inserting an ADI4 DP slave in the configuration
Procedure
1. To insert an ADI4 DP slave in the configuration, open the hardware catalog using the
34
After inserting the ADI4 DP slave in the configuration, the following parameters are
assigned on a slave-specific basis:
– PROFIBUS parameters (see Section "PROFIBUS parameters (Page 35)")
– Function parameters (see Section "Function parameters (Page 43)")
Step 1 should be carried out first for all ADI4 DP slaves needed in the configuration.
Parameter assignment of the equidistant cyclic DP communication (see Section
"Parameter assignment of the DP communication (Page 55)")
Step 2 can be performed last on any ADI4 DP slave. These settings can be transferred to
all other ADI4 DP slaves by means of the adjustment function of the SlaveOM.
View > Catalog menu command.
The ADI4 DP slave can be found at:
– Profile: Standard
PROFIBUS DP > SINUMERIK > ADI4
SIMATIC Technology CPU
If S7-Technology was installed for the Technology CPU, the ADI4 DP slave is located
under:
– Profile: SIMATIC Technology CPU
PROFIBUS DP (DRIVE) > Other FIELD DEVICES > SINUMERIK > ADI4
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
Manual, 05/2009, 6FC5 297-0BA01-0BP6