• When using an external power supply for transistor output
Sink logic
Use terminal PC as a common terminal, and perform wiring as
follows. (Do not connect terminal SD on the inverter with the
terminal of 0 V for the external power supply. When using
terminals PC-SD as a 24 VDC power supply, do not install an
external power supply in parallel with the inverter. Doing so
may cause a malfunction in the inverter due to undesirable
currents.)
QY40P type transistor
output unit
Constant
voltage
circuit
2.6.5

Wiring of control circuit

 Control circuit terminal layout
 Standard model
• Recommended cable gauge: 0.3 to 0.75 mm
*1
Terminal FM is available for the FM type inverter. Terminal AM is available for the AM type inverter.
*2
Terminal SD is available for the FM type inverter. Terminal 5 is available for the AM type inverter.
52
2. Installation and Wiring
2.6 Control circuit
Inverter
STF/
TB1
DI0
24 VDC
(SD)
STR/
TB2
DI1
TB17
PC
TB18
24 VDC SD
Current flow
2
Source logic
Use terminal SD as a common terminal, and perform wiring as
follows. (Do not connect terminal PC on the inverter with the
terminal of +24 V for the external power supply. When using
terminals PC-SD as a 24 VDC power supply, do not install an
external power supply in parallel with the inverter. Doing so
may cause a malfunction in the inverter due to undesirable
currents.)
QY80 type transistor
output unit
Constant
voltage
Fuse
circuit
S1 S2 PC RUN FU SE
MRS RES SD STF
RL RM RH SD
A
B
C
Inverter
PC
TB1
STF/DI0
24 VDC
(SD)
TB2
STRDI1
TB17
TB18
SD
Current flow
STR


SO
SOC
10
2
5
4