2.
Crimp the terminals on the wire.
Insert wires to the crimp terminal, and check that the wires come out for about 0 to 0.5 mm from a sleeve.
Check the condition of the crimp terminals after crimping. Do not use the crimp terminals of which the crimping is
inappropriate, or the face is damaged.
Crimp terminals commercially available (as of December 2019)
• Phoenix Contact Co., Ltd.
Wire gauge
2
(mm
)
With insulation sleeve
0.3
AI 0,34-10TQ
0.5
AI 0,5-10WH
0.75
AI 0,75-10GY
1
AI 1-10RD
1.25, 1.5
AI 1, 5-10BK
0.75 (two-wire
AI-TWIN 2×0,75-10GY
product)
• NICHIFU Co., Ltd.
Wire gauge
2
(mm
)
0.3 to 0.75
3.
Insert the wire into the terminal block.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
54
2. Installation and Wiring
2.6 Control circuit
Ferrule part No.
Without insulation
sleeve
A 0,75-10
A 1-10
A 1, 5-10
Blade terminal part
Insulation cap part No.
No.
BT 0.75-11
VC 0.75
Damaged
Crumpled tip
Crimping tool
model No.
CRIMPFOX 6
Crimping tool model
No.
NH 69
When using single wire or stranded wire without crimp terminal,
push an open/close button all the way down with a flathead
screw driver, and insert the wire.
Unstranded
wires
Wires are not inserted
into the sleeve
Open/close button
Flathead screwdriver