LUNA2000-(5-30)-S0
User Manual
Avoid scratching the core wire when stripping a cable.
The cavity formed after the conductor crimp strip of the OT terminal is crimped must wrap
the core wires completely. The core wires must contact the OT terminal closely.
Wrap the wire crimping area with heat shrink tubing or insulation tape. The heat shrink
tubing is used as an example.
When using a heat gun, protect the equipment from being scorched.
Figure 5-6 Crimping an OT terminal
(A) Core wire
(D) Hydraulic pliers
Step 2 Ground the PE cable.
Issue 01 (2020-09-18)
(B) Insulation layer
(E) Heat gun
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connection
(C) Heat shrink tubing
52