Figure 3-2 Power distribution conceptual diagram for the 220 V single-phase scenario with the 6
kVA/10 kVA UPS
The power distribution system meets the power supply requirements of single-phase 220
V/230 V/240 V.
Table 3-2 Power distribution system technical specifications
Item
Rated power
Rated input voltage
Rated frequency
Maximum input
current
External input
power distribution
circuit breaker
Issue 05 (2019-11-22)
Specifications (10
kVA UPS)
9 kW
220 V/230 V/240 V
50 Hz/60 Hz
50 A
63 A
Copyright © Huawei Technologies Co., Ltd.
Specifications (6
kVA UPS)
5.4 kW
220 V/230 V/240 V
50 Hz/60 Hz
32 A
50 A
3 System Architecture
Specifications (3
kVA UPS)
2.7 kW
220 V/230 V/240 V
50 Hz/60 Hz
19 A
32 A