Appendix A: Control register list ④
Address
Register name
7080h WhiteCorrectionExecute
WhiteCorrectionExtra
7084h
Triger
70A0h DegitalGainEnable
70A4h DegitalGain_R
70A8h DegitalGain_G
70ACh DegitalGain_B
70B0h ResolutionSetting
LineAdjustment
70C0h
Enable
70C4h LineAdjustmentDirection
70C8h LineAdjustmentRatio
70CCh LineAdjustmentOfset
TM-XJ959A
R/W
Parameter
Data
R/W
1
Generate White Correction data (Normal Trigger mode)
Generate White Correction data (External Trigger mode)
R/W
0 or 1
0:END / 1:START
Set Degital Gain On/Off
R/W
0 or 1
0:OFF /1:ON
Set a value of Red PGA (0 to 4.0)
R/W -1024 to 3071
R/W -1024 to 3071 Set a value of Green PGA (0 to 4.0)
R/W -1024 to 3071 Set a value of Blue PGA (0 to 4.0)
Set Resolution and Interpolation On/Off
0: 600dpi, Interpolation ON
1: 600dpi, Interpolation OFF
R/W
0 to 4
2: 300dpi mode
3: 200dpi mode
4: 150dpi mode
※Interpolation is not supported on 300,200, and 150dpi modes.
Set Line adjustment On/Off
R/W
0 or 1
0:OFF /1:ON
Set transport direction
0: Normal (B → G → R :B-line first)
R/W
0 or 1
1: Opposit (R → G → B :R-line first)
Resolution in transport direction/600dpi Ratio (0.03 to 4.0)
R/W
1 to 16384
LineAdjustmentRatio =
Offset setting of Green pixel (0 to 1.0)
R/W
0 to 4096
Function
ܴ݁݃݅ ‫݁ݑ ݈ܽݒ ݎ݁ ݐݏ‬
Resolution(transport direction)
ܱ݂݂‫= ݐ݁ݏ‬
4096
© Mitsubishi Electric Corporation
Initial
-
0
0
0
0
0
1
1
0
4096
/600dpi×4096
0
93