Download Print this page

Troubleshooting - Aqualisa SMART Installation Manual

Advertisement

TROUBLESHOOTING

Symptom
Controller LED's
flashing and
changing colour
when power turned
on to the Aqualisa
SmartValve
TM
Controller
unresponsive -
No Lights / Blank
Controller
displaying
"Preparing, please
wait...." for longer
than 2 minutes
Pump noisy and
low / no flow
Possible cause Action
Start up sequence
and controller
configuration in
process (controller
specific)
Power supply turned
off to Aqualisa
SmartValve
TM
Loss of
communications
Air lock (for Gravity
fed systems only)
No action required - sequence and configuration
can last up to 2 minutes. Wait until LED's go out
and then the controller is ready to use.
Check power supply is turned on - Green power light
should be illuminated on the Aqualisa SmartValve
Check data cable connections are making good
contact and are fully inserted.
Check that the wiring schematics are as per
installation instructions.
For models utilising a adjustable head kit; disconnect
the handset from the hose, lower the hose into the
shower tray or bath, set the temperature to fully
cold and then start the shower. As the water starts
to flow and increase in volume gradually increase
the temperature. If the flow starts to splutter, stop
moving the temperature control until the flow again
stabilises, then continue to move the dial towards
the hottest setting.
Isolate hot and cold feeds to the Aqualisa
SmartValve
, disconnect from the inlet spigots and
TM
then using the isolation valve bleed through the hot
and cold supplies.
Release the outlet pipe work from the outlet
isolation valve of the Aqualisa SmartValve
an appropriate connection, flexi or length of pipe
connect to the isolation valve so that water can be
discharged into a bucket or suitable receptacle. Start
the shower and bleed through until air is cleared.
.