Page 3
Components Components (exposed) Literature not shown. Components (concealed) Literature not shown. Aqualvalve 700 Thermo installation instuctions page 3...
A cold inlet flow regulator is provided for use with instantaneous (multipoint) gas water heater and combination boiler applications. If you have any questions at any stage during installation please contact the Aqualisa customer helpline on 01959 560010 for advice.
9 litres (2 gallons) per minute to the shower valve. This is sufficient to operate one outlet point at a time. The Aqualisa Thermo cartridge is designed to operate from the mains at a maximum of 10 bar. If the mains pressure exceeds 10 bar a ‘drop tight’...
Page 6
Step -by-step instructions Exposed valve In addition to the guide below it is essential that the written instructions overleaf are read and understood and that you have all the necessary components (shown overleaf) before commencing installation. Failure to install the product in accordance with these instructions may adversely affect the warranty terms and conditions.
Page 7
Remove the fixing template. Using a rotary type cutter cut the inlet pipes to length and drill and prepare the fixings for the mounting ring. Fix the mounting ring to the wall using the screws provided. Briefly run the hot and cold supplies to flush out any debris that may be present in the system.
Page 8
Tighten the elbow locking screws using 2.5mm key provided. Slide the dummy nuts into position and rotate them so the locking screw is out of site before securing them using the 2.5mm key. Tighten the inlet compression unions sufficiently to ensure a watertight seal. Push the cover plates over the unions flush to the wall surface.
Page 9
Follow steps 6 to 14 listed above. Concealed valve In addition to the guide below it is essential that the written instructions overleaf are read and understood and that you have all the necessary components (shown overleaf) before commencing installation. Failure to install the product in accordance with these instructions may adversely affect the warranty terms and conditions.
Page 10
Suitable non-setting infill material such as paper, polystyrene etc. should be wrapped around the components and a plaster finish applied. Aqualisa reserves the right to revoke the terms of the warranty should access to service connections be denied by the use of solid setting infill material.
Page 11
Fit the temperature lever to the valve body with the lever in a vertical position. Secure with the four screws hand tight only. Push the on/off know onto the valve fully home ensuring the badge recess is horizontal and the finger grips are correctly orientated.
Remove the screw and pull the knob clear. Should unacceptable damage to the badge occur when removing it from the recess, please contact Aqualisa customer services who will send a free of charge replacement.
After installation Run through the valve operation with the purchaser and hand them this guide. Complete and post the Aquavalve 700 Thermo guarantee card or register online at www.aqualisa.co.uk. Cleaning Your Aquavalve 700 Thermo shower valve should be cleaned using only a soft cloth and washing up liquid.
Page 14
Typical installations Typical gravity system installation Typical Thermal storage unit system installation Supply Underside of cistern Vent and draw-off pipe to hot water Highest point Cold feed must be 1m below to cylinder underside of cistern Connect ‘A’ or ‘B’ Supply Hot water Hot water...
Page 15
Brochure Hotline: 0800 652 3669 Website: www.aqualisa.co.uk Email: enquiries@aqualisa.co.uk Please note that calls may be recorded for training and quality purposes The company reserves the right to alter, change or modify the product specifications without prior warning ® Registered Trademark Aqualisa Products Limited...