User Guide; Shower Operation; Trouble Shooting Guide - Aqualisa Aquastream Thermo Installation Instructions Manual

Thermostatic integral power shower
Hide thumbs Also See for Aquastream Thermo:
Table of Contents

Advertisement

User guide

Shower operation

Turn the on/off knob anti-clockwise to the 'Normal' flow position which will automatically start the pump
operation. For increased flow and pressure continue to turn the control knob anti-clockwise to the 'Boost'
position.
Normal
Turn the control knob fully clockwise to turn the shower off.
When set vertically, the temperature lever is in the mid-blend position, the hot and cold supply temperatures will
dictate the actual heat setting in this position. Temperature adjustment is made by rotating the lever according
to the red and blue temperature markings.
The maximum operating periods for this shower are 15mins on, 45mins off.

Trouble shooting guide

Symptom
Pump fails to start
Pump runs but performance
is poor
Water output is either all
hot or all cold
Water output is not hot
enough
Aquastream Thermo thermostatic integral power shower installation instuctions
Boost
Possible cause
Action
No power supply to the
Check the fuse in the spur
pump
box or plug
Check transformer cut-out
Water flow is being impeded
Check for debris in shower
head
Check that the hose is not
twisted
Reversed inlet supplies
Check that the pipe work is
laid out in accordance with
the correct practices paying
particular attention to
potential air traps
The temperature of the hot
The cylinder temperature
water cylinder is too low
should be at least 15ºC
hotter than the desired blend
page 13

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquastream Thermo and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF