Failure Code [Ca441] Battery Voltage Low Error; Failure Code [Ca442] Battery Voltage High Error - Komatsu Galeo PC800-8 Shop Manual

Hydraulic excavator
Table of Contents

Advertisement

40 Troubleshooting
Troubleshooting by failure code (Display of code), Part 2

Failure code [CA441] Battery Voltage Low Error

Action code
Failure code
E10
CA441
Contents of
• Low voltage error occurred in power supply circuit.
trouble
Action of
• None in particular.
controller
Problem that
appears on
• Operations are continued, but engine may stop during operations or may not start in stopped state.
machine
Related
• Power supply voltage can be checked with monitoring function
information
(Code No. 03200: Power supply voltage).
Possible causes
and standard
value in normal
state

Failure code [CA442] Battery Voltage High Error

Action code
Failure code
E10
CA442
Contents of
• High voltage error occurred in power supply circuit.
trouble
Action of
• None in particular.
controller
Problem that
appears on
• Operations are continued, but engine may stop during operations or may not start in stopped state.
machine
Related
information
Possible causes
and standard
value in normal
state
PC800, 850-8
Battery Voltage Low Error
Trouble
(Engine controller system)
Cause
Carry out troubleshooting for failure code [CA111].
Battery Voltage High Error
Trouble
(Engine controller system)
Cause
Carry out troubleshooting for failure code [CA111].
Standard value in normal state/Remarks on troubleshooting
Standard value in normal state/Remarks on troubleshooting
SEN00791-02
3

Advertisement

Table of Contents
loading

Table of Contents