A p p E N D I X C
Gas phase compensation static factors
The following tables explain provide the necessary gas phase compensation (GPC) static factors.

Dielectric constant of steam

Temperatrure
°C
°F
1 bar
14.5 psi
100
212
1.005806
120
248
1.005227
152
306
1.004476
180
356
1.003950
212
414
1.003458
264
507
1.002840
311
592
1.002418
366
691
1.002036

Example with steam: resulting error in the gas phase

Gas phase
Temperatrure
°C
Steam
100
(water vapor)
120
152
180
212
264
311
366
2 bar
5 bar
29 psi
72.5 psi
1.010601
1.009048
1.023424
1.007964
1.020432
1.006960
1.017743
1.005705
1.014456
1.004851
1.012252
1.004082
1.010283
°F
5 bar
5 bar
72.5 psi
72.5 psi
212
0.26%
248
0.23%
0.50%
306
0.20%
0.42%
356
0.17%
0.37%
414
0.15%
0.32%
507
0.12%
0.26%
592
0.09%
0.22%
691
0.07%
0.18%
Pressure
10 bar
20 bar
145 psi
290 psi
1.042934
1.036765
1.079856
1.029597
1.062307
1.024933
1.051729
1.020834
1.042799
Pressure
5 bar
5 bar
5 bar
72.5 psi
72.5 psi
72.5 psi
1.14%
0.99%
2.10%
0.86%
1.79%
3.9%
0.69%
1.44%
3.0%
0.58%
1.21%
2.5%
0.49%
1.01%
2.1%
50 bar
100 bar
725 psi
1450 psi
1.192220
1.147384
1.424747
1.116952
1.282623
5 bar
5 bar
72.5 psi
72.5 psi
9.2%
7.1%
19.3%
5.7%
13.2%
200 bar
2900 psi
3.086361
5 bar
72.5 psi
79%