Input Registers - ABB LWT300 Series User Manual

Guided wave radar level transmitter
Hide thumbs Also See for LWT300 Series:
Table of Contents

Advertisement

Input registers

The input registers consist of 16 bits. They can only be read out. The address (1 byte) is sent before
each command. A CRC (2 bytes) is sent after each command. PV, SV, TV and QV can be adjusted via the
sensor FDI.
Register name
Register
address
Status
100
pV Unit
104
pV
106
SV Unit
108
SV
110
tV Unit
112
tV
114
QV Unit
116
QV
118
Status
1300
pV
1302
SV
1304
tV
1306
QV
1308
advanced Status
1310
advanced Status
1311
advanced Status
1312
Diagnostic
1314
Diagnostic
1315
Diagnostic
1316
Diagnostic
1317
Status
1400
pV
1402
Status
1412
SV
1414
Status
1424
tV
1426
Status
1436
QV
1438
B90 User Guide
Data type
Swap mode
UINT16
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
Float32
Reg. 3000
Float32
Reg. 3000
Float32
Reg. 3000
UINT16
UINT16
UINT16
UINT16
UINT16
UINT16
UINT16
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
UINT16
Float32
Reg. 3000
Description
Bit 0: Invalid Measurement Value pV
Bit 1: Invalid Measurement Value SV
Bit 2: Invalid Measurement Value tV
Bit 3: Invalid Measurement Value QV
Unit code based on haRt spec - Check UnitCode tab
primary Variable in Byte Order of Register 3000
Unit code based on haRt spec - Check UnitCode tab
Secondary Variable in Byte Order of Register 3000
Unit code based on haRt spec - Check UnitCode tab
third Variable in Byte Order of Register 3000
Unit code based on haRt spec - Check UnitCode tab
Quarternary Variable in Byte Order of Register 3000
See register 100
primary Variable in Byte Order of Register 3000
Secondary Variable in Byte Order of Register 3000
third Variable in Byte Order of Register 3000
Quarternary Variable in Byte Order of Register 3000
the device status is obtained from the first 6 bytes of
haRt command 48
the device status is obtained from the first 6 bytes of
haRt command 48
the device status is obtained from the first 6 bytes of
haRt command 48
Obtained from haRt command 9, pV_Status
Obtained from haRt command 9, SV_Status
Obtained from haRt command 9, tV_Status
Obtained from haRt command 9, QV_Status
See register 100
primary Variable in Byte Order of Register 3000
See register 100
Secondary Variable in Byte Order of Register 3000
See register 100
third Variable in Byte Order of Register 3000
See register 100
Quarternary Variable in Byte Order of Register 3000

Advertisement

Table of Contents
loading

Table of Contents