Configuration With Graphical User Interface (Dtm); Standard And Advanced Hart: Functionality; Advanced Hart Software Revision History; Standard Hart Software Revision History - ABB 266 HART Series Operating Instruction

Pressure transmitters
Hide thumbs Also See for 266 HART Series:
Table of Contents

Advertisement

For additional information, refer to the operating instructions
included with the handheld terminal.
If the transmitter has been configured in the factory according
to customer specifications for the measuring point, all you have
to do is mount the transmitter as prescribed (to correct
potential zero shifts, refer to the section "Correcting the zero
shift"), and switch it on. The measuring point will now be ready
for use.
If, however, you wish to make changes to the configuration, a
handheld terminal or - preferably - a graphical user interface
(DTM) is required. This DTM tool renders the device fully
configurable. It supports both the HART protocol and
PROFIBUS PA fieldbus protocol, and can be run on a PC or
laptop, or as part of an automation system. Where
FOUNDATION Fieldbus is concerned, the device description
(DD), which can be loaded onto various configuration tools, is
required for configuration purposes.
Refer to the installation manual provided with the software for
the steps required to install the operating tool. The most
important parameters can be set via the path "Parametrize_
Differential Pressure Measurement".
The program offers the option of configuring, polling, and
testing the transmitter.
In addition, offline configuration can be performed by means of
an internal database.
Each configuration step is subject to a plausibility check. You
can call up context-sensitive help at any time by pressing the
"F1" key. Immediately after you have received the transmitter or
before you change the configuration, we recommend that you
save the existing configuration data to a separate data storage
medium, via the path "File_Save".
8.17 Configuration with the graphical user interface
(DTM) - System requirements
— Operating control program (e.g., ABB Asset Vision Basic
version 1.00.17 or higher)
— DTM (Device Type Manager; graphical user interface)
— Operating system (depending on the respective control
program)
To operate the Asset Vision Basic please refer to the relevant
operating instruction.

8.18 Standard and Advanced HART: functionality

266 Pressure Transmitters can be codified with:
— Advanced HART and 4 to 20 mA
— Standard HART and 4 to 20 mA
— HART and 4 to 20 mA Safety, certified to IEC 61508
Advanced and Standard HART feature some differencies in
terms of functionality.
Functionality
266 Advanced HART 266 Standard HART
Configuration via HMI
On board
SIL certified
On board
PILD
On board
Trend
On board
Totalizer
On board
Service Port
On board
Electronic replacement
On board
60 OI/266/HART-EN Rev. M | 2600T Series Pressure transmitters

8.19 Advanced HART software revision history

Revision
From
7.1.11 7.1.12
7.1.12 7.1.14
7.1.14 7.1.15
7.1.15 7.2.1
7.1.15
7.2.1

8.20 Standard HART software revision history

Revision
From
7.1.52 7.1.53
7.1.53 7.1.54
7.1.54 7.1.55
Not available
7.1.55 7.1.56
Not available
7.1.56 7.2.50
On board
7.1.56 7.1.74
Not available
7.2.50 7.2.54
On board
Not available
Not available
Intermediate releases for internal tests not published
Description
To
7.1.11 First release
Bug Fixing:
— microbar and millitor units added
— HART command 35 bug fixed. By HART
specificaiton #35 unit should not be set pv unit
— if the local indicator was not mounted, only
one operation via push buttons was performed
— MWP diagnosis classification become
Maintenance instead of Off-Specification
Improvements:
— replacement functionality improved
— internal improvements to reduce factory
configuration
— more/stronger checks about process variables
goodness
— HART response time reduced (30%)
Improvements:
— factory configuration speeded up
— service detailed diagnosis implemented
Bug Fixing:
— sensor trimming via local display was
performend only in kPa
— diagnosis "Replace Error" no more shown
— unit strings on display (Nm3, bbl, t) were wrong
New Features:
— new language (French & Spanish) on local
indicator
— sensor polarity invertion
HART 7 implementation
7.1.16
New Features:
(HART 5)
— Temperature alarm enabled by user
7.2.2
— oscillation alarm control
(HART 7)
— switching of alarm for wrong power supply
Description
To
7.1.50 First release
7.1.51 Internal release not published
7.1.52 Internal release not published
Bug Fixing:
— HART burst mode
— correcting Custom unit visualization on LCD
Improvements:
— boot loader performance
— HART secondary response code
— Electronics temperature reading
Integrated LCD firmware integration
Bug fixing on EEPROM
Obsolete Microprocessor replacement
HART 7 Introduction
Several bug fixing
(HART 5)
Several bug fixing and certification
(HART 7)
HART burst mode removed
8 Operation
Release
date
09/2009
06/2010
01/2011
01/2013
11/2015
10/2018
Release
date
02/2013
01/2014
07/2014
10/2014
06/2016
10/2016
10/2018