Drive Error Diagnostics - Bosch Rexroth CKL Series Commissioning

Drive controller
Table of Contents

Advertisement

Drive Error Diagnostics

31
18 Drive Error Diagnostics
18.1 Fix drive error/fault (example)
18.1.1 Steps for drive error diagnostics:
1. Start Easy Startup Mode (PM → OM) failed.
2. Axis status indicates a drive error, in this example F8022 encoder error message.
3. Select the Help icon for a description of the error, possible cause, and remedy (e.g. check
encoder cable is securely connected to drive).
4. After checking possible remedy, set drive to Parameter mode.
5. Clear error.
6. Re-try Start Easy Startup Mode (PM → OM).
7. If Axis status indicates another error, repeat steps 3 to 6.
01.2015, USL00010, Bosch Rexroth Corp.