Usage For Configuration Or As Process Interface; Transmission Parameters Of The Interface - ABB EDS500 Series Function Manual

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Serial Interfaces
• 8N1( 8 data bits, no parity, 1 stop bit)
• no flow control
2.20.1

Usage for Configuration or as Process Interface

The default value for the serial interfaces is: configuration.
The setting configuration allows to access the management console with its command
line interface (CLI). An alternative use as process interface can be set with a command. The
following modes are available.
Mode
Parameter
Configura-
tion
configura-
tion
Modem
modem
Tunnel
tunnel
IEC101
iec101
Linetest
linetest
Loopback
loopback
Table 25:
Operating modes
Commands to configure the operation mode of the serial interface
< s e t i n t e r f a c e { c o n s o l e 0 | c o n s o l e 1 } m o d e { c o n f i g u r a t i o n |
i e c 1 0 1 | l i n e t e s t | l o o p b a c k | m o d e m | t u n n e l } >
2.20.2

Transmission Parameters of the Interface

The parameters of the serial interface can be set by command for baud rate (300, 600, 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200 or 230400), data bits (5, 6, 7 or 8), parity
(none, even, odd, mark or space) and stop bits (1 or 2). Also the behaviour of the control
signals CTS and DCD can be set. The DCD signal can be inverted on hardware level.
DCD lead times and follow-up times can be set for switching the carrier on or off if an
external modem is used. For this purpose DCD has to be set to while-tx. The DCD lead time
has an additional purpose for the operation mode "tunnel", refer to "Serial Tunnel" .
TX
DCD
Figure 19: DCD lead time and follow-up time
58
Description
The interface allows offers access to the command line interface (CLI) to con-
figure the device. This is the default value.
The interface emulates an AT dial-up modem that can establish a link to
another emulated modem by using the IP address as dialled number.
The interface transports serial data streams to one or more remote devices.
There, the data is output at the remote serial interface.
The interface is set to telecontrol mode and can be attached to a IEC
60870-5-101 interface.
The interface generates a test pattern that is sent continuously. With the com-
mand line interface (CLI) it can be monitored whether the interface receives
the test pattern correctly or whether the link is interrupted.
The interface returns all received data immediately.
DCD Setup time
DCD Follow-Up time
1KGT151021 V000 1
Functions