Mounting The Stator Segments - Siemens SIMOTICS-T 1FW68 Engineering Manual

Segment motors, radial for sinamics s120
Table of Contents

Advertisement

Configuring
5.2 Mounting
5.2.4.2

Mounting the stator segments

A stator segment has four T-slots for mounting it.
1. Mount two T-sliding blocks and two extended T-sliding blocks into the mounting surface
of the machine as shown in the following diagram. The extended T-sliding blocks help to
correctly slide in the segments. This prevents the stator segments from being canted
when inserted.
2. Using the appropriate mounting equipment, slide the stator segment onto the T-sliding
blocks. Protect the rotor segments against damage using a spacer foil 1 mm thick.
108
T-sliding block
Extended T-sliding block (helps insertion)
T-slot
Machine mounting surface
WARNING
Danger of severe crushing injuries
As soon as the stator segment enters the magnetic field of the rotor segments, the
stator segment is very suddenly and quickly drawn towards the rear. There is significant
risk of crushing injury
• Do NOT mount the stator segments by hand. Use suitable mounting equipment. At
any time during the mounting procedure, this mounting equipment must absolutely
ensure that the stator segment can be evenly and slowly inserted into the T-sliding
blocks.
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1