Mounting/Installation; Requirements For The Electrician; Mounting; System Security - ABB 83330-5 Series Product Manual

Telephone gateway
Table of Contents

Advertisement

ABB-Welcome
6

Mounting/Installation

P os : 34 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Siche rheit (- -> Fü r alle D okument e <--) /W ar nh inweis e/Siche rheit - Nie der s pan nungs- und 2 30 V -Leitung en @ 18\ mod_13 026 17 8 214 91_ 1 5.d ocx @ 103 46 5 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or indirect contact with live
components.
This can result in electric shock, burns or even death.
■ Disconnect the mains power supply prior to installation and/or disassembly!
■ Permit work on the 110-240 V supply system to be performed only by specialist staff!
P os : 35 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Siche rheit (- -> Fü r alle D okument e <--) /W ar nh inweis e/Siche rheit - V o rges c halte te S iche rung a bscha lt en @ 20 \ mo d_1 3 264 417 1 14 67_ 15 .d ocx @ 137 043 @ @ 1
Warning
Electric voltage!
The upstream fuse must be disconnected when working on the lighting system.
P os : 36 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Siche rheit (- -> Fü r alle D okument e <--) /W ar nh inweis e/Siche rheit - Fachkenn tnisse @ 18 \mod_1 302 7 74 384 01 7_ 15. doc x @ 10 3 56 4 @ 2 @ 1
6.1

Requirements for the electrician

Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
Incorrect installation endangers your life and that of the user of the electrical system.
Incorrect installation can cause serious damage to property, such as a fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1.
Disconnect the power;
2.
Secure against being reconnected;
3.
Ensure there is no voltage;
4.
Connect to earth;
5.
Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the type of supply network (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
P os : 37 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Übe rsch ri f te n ( --> Fü r alle Doku mente < -- )/2. E bene /M - O/ Montage @ 18\m od_1 3 02 615 96 0 458 _15 . docx @ 10 342 4 @ 2 @ 1
6.2

Mounting

P os : 38 /B usc h-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Monta ge/alle Ge räte/M ontage - UP -Dos en - DIN 4 907 3 -1 ode r geeign ete s A ufput z geh aeu s e - Ohn e Docv ariable @ 20 \ mod _13257 6603445 3_1 5. d ocx @ 1 365 93 @ @ 1
The device must only be installed on mounting rails according to DIN EN 50022.
6.3

System security

Avoid misuse by intruders and configure your telephone system in a way that the telephone gateway cannot
directly be called from an external telephone. This will prevent unauthorized access of intruders.
If it is necessary to have external access to the gateway, please activate the indoor station PIN. (See page 9.)
P os : 39 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Steu er mo d ule - On lin e-Dokume ntati o n ( -- > F ü r alle Dokume nte <- -)/ +++ + + ++ +++ + + S eitenumb ruch + +++ ++ + + +++ + @ 9\m od_126 8898668 093 _0 . docx @ 521 49 @ @ 1
— 8 —

Advertisement

Table of Contents
loading

This manual is also suitable for:

83350-500