ABB 83330-5 Series Product Manual

ABB 83330-5 Series Product Manual

Telephone gateway

Advertisement

Quick Links

V1.2 ││ 28.04.2017
ABB-Welcome
P os : 2 /B usch-Ja ege r (N eust ru kt ur)/ Mo d ul-S t ruktur/Onli ne- D oku men t ation /Ti t el blätt er/ D i mme r/T i telblat t - 659 1 U- 1 01 -- A BB @ 2 3\ m od_ 1333088 838540 _15 .d ocx @ 20702 5 @ @ 1
Telephone gateway
83350-500
=== E nde de r Liste für Tex tmarke C over == =

Advertisement

Table of Contents
loading

Summary of Contents for ABB 83330-5 Series

  • Page 1 V1.2 ││ 28.04.2017 ABB-Welcome P os : 2 /B usch-Ja ege r (N eust ru kt ur)/ Mo d ul-S t ruktur/Onli ne- D oku men t ation /Ti t el blätt er/ D i mme r/T i telblat t - 659 1 U- 1 01 -- A BB @ 2 3\ m od_ 1333088 838540 _15 .d ocx @ 20702 5 @ @ 1...
  • Page 2: Table Of Contents

    ABB-Welcome P os : 4 /B usch-Ja ege r (N eust ru kt ur)/ Mo d ul-S t ruktur/Onli ne- D oku men t ation /In h altsve rz eich nis (--> Fü r all e Doku m en te <-- ) / In haltsverzeic hnis @ 19\ m od _13 206490 44386_1 5.d o cx @ 109653 @ @ 1 Safety ................................3...
  • Page 3: Safety

    ABB-Welcome P os : 6 /B usch-Ja ege r (N eust ru kt ur)/ Mo d ul-S t ruktur/Onli ne- D oku men t ation /Übe rschri ft e n (- -> F ür alle D o kum ent e < --)/ 1. Eb ene/S - T /S icher h eit @ 18 \ mod _13026 127 9 17 90_ 15. d ocx @ 1 03 357 @ 1 @ 1 Safety P os : 7 /B usch-Ja ege r (N eust ru kt ur)/ Mo d ul-S t ruktur/Onli ne- D oku men t ation /Sicher heit (-- >...
  • Page 4: Technical Data

    ABB-Welcome P os : 13 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Übe rsch ri f te n ( --> Fü r alle Doku mente < -- )/1. E bene /S - T/T echn isc he D a ten @ 1 1 \m od_1 2 79 185 38 6 320 _15.docx @ 8 3 019 @ 1 @ 1 Technical data P os : 14 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Technis ch e D aten / D imm er/Tec hnische Dat en - 65 91 U - 101 @ 23\mo d_1333 089 0 85 280 _15 .
  • Page 5: General Function

    The 83350 telephone gateway is part of the ABB-Welcome door communication system and operates exclusively with components from this system. This product connects a telephone system to the ABB-Welcome system so that the connected telephones function as audio indoor stations.
  • Page 6: Connection

    P os : 31 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Anschl uss /Dim me r / A nschl u ss - 659 1 U- 101 @ 23 \mo d _1 333 093 9 200 08_15.d ocx @ 207 13 2 @ @ 1 Fig. 1 Function Terminals for ABB-Welcome system Terminals (Telephoneline clamps) for Private Branch Exchange (PBX) in telephone system Note: The telephone gateway is always set as master.
  • Page 7: Device Overview

    Operation status of connection to PBX Connected to PBX (idle or call in progress) : a. Ringing Operation status of ABB-W elcome bus : Ready for operation. Bus voltage is applied. : a. Receiving data : Reset to factory defaults (ongoing) USB port for software update (can only be done at the factory).
  • Page 8: Mounting/Installation

    ABB-Welcome Mounting/Installation P os : 34 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Siche rheit (- -> Fü r alle D okument e <--) /W ar nh inweis e/Siche rheit - Nie der s pan nungs- und 2 30 V -Leitung en @ 18\ mod_13 026 17 8 214 91_ 1 5.d ocx @ 103 46 5 @ @ 1...
  • Page 9: Commissioning

    P os : 41 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/I n bet riebnahm e/Dimme r/Inbetri ebn ah m e - 6591 U-1 01 @ 19\ mod_1 3119487 810 23 _ 15.d oc x @ 108 3 00 @ 2 2 2 @ 1 The following components are required to operate the telephone gateway: - ABB-Welcome door communication system including the system controller and at least one outdoor station. - A PBX with analog input - At least one telephone for configuring via DTMF For the initial startup of the telephone gateway, a few basic settings need to be made.
  • Page 10 ABB-Welcome Set new indoor station [*] Indoor station Number [*] [7] [*] PINs New Indoor station PIN [*] New Indoor station PIN [#] Set telephone gateway [7] [4] [3] [*] Identifier [*] Identifier [#] Identifier should be a number from 1 to 99, identifier for and must be unique.
  • Page 11: Operation

    ABB-Welcome P os : 43 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nline-Doku mentatio n/Übe rsch ri f te n ( --> Fü r alle Doku mente < -- )/1. E bene /A - F/B edienun g @ 11\ mod_ 1 27 918 55 4 164 9_15.doc x @ 8 304 3 @ 1 @ 1 Operation P os : 44 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nlin e -Doku mentatio n/Bedi enung/Dim mer/B edie nu n g - 6591 U-1 01 @ 23\ mod_13 330 9 12 931 58 _ 15.d ocx @ 207 0 69 @ @ 1...
  • Page 12 ABB-Welcome [*] Indoor station number [*] Control switch actuator when Indoor station PIN [*] [5] [1] [#] to [5] [199] indoor station PIN is required Activate default phone [*] Indoor station number [*] [6] [0] [#] number Activate Default phone...
  • Page 13: Tones For Indication

    ABB-Welcome Tones for indication Function Tones Explanation Confirmation of a successful Successful operation Notification of an unsuccessful Not successful operation Doorcall waiting (only when direct accept feature is deactivated if no Doorcall (repeating) indoor stations in the same appartment) Call divert to the default number Call divert activated is activated.
  • Page 14: Appendix

    ABB-Welcome Appendix 10.1 Frequently-used commissioning Use case: One apartment with one telephone + one telephone gateway. User uses phone to call telephone gateway firstly, then Function Command Example or explanation Step 1 Enter admin PIN [*] [*] [*] + Admin PIN + [#]...
  • Page 15 W e reserve the right to, at any tim e, make technical changes or changes in the content of this document without prior notice. The det ailed specifications agreed to at the time of ordering applies to all orders. ABB accepts no responsibility for possible errors or incompleteness in this docum ent.