Operation

P os : 44 /B us ch-J aeg e r (Neus tru k tur )/M o dul -S truk t ur/O nlin e -Doku mentatio n/Bedi enung/Dim mer/B edie nu n g - 6591 U-1 01 @ 23\ mod_13 330 9 12 931 58 _ 15.d ocx @ 207 0 69 @ @ 1
After programming, users can use a telephone to call the telephone gateway.
When there is a call-in from outdoor station, and telephone is in normal standby:
No.
Function
Accept call-in
1
Commands below can be done via telephone when there is ongoing conversation between outdoor station and
telephone:
No.
Function
Open default lock
1
Open the second lock
2
Control switch actutor
3
When there is no ongoing conversation between outdoor station and telephone, user calls the telephone gateway,
then
1. When call divert to default phone number is activated, the telephone will play "calls are diverted" tone;
2. When call divert to default phone number is deactivatedd, the telephone will play "calls are not diverted" tone.
3. Settings below can be done via telephone:
No.
Function
Call outdoor station
1
Call outdoor station when
indoor station PIN is
2
required
Call the last call-in outdoor
3
station
Call the last call-in outdoor
station when indoor station
4
PIN is must
Open the default lock of the
5
specific outdoor station
Open the default lock of the
specific outdoor station when
6
indoor station PIN is required
Open the default lock of the
7
last call-in outdoor station
Open the default lock of the
last call-in outdoor station
8
when indoor station PIN is
required
Open second lock of the
9
specific outdoor station
Open the second lock of the
specific outdoor station when
10
indoor station PIN is required
Open the second lock of the
11
last call-in outdoor station
Open the second lock of the
last call-in outdoor station
12
when indoor station PIN is
required
Call guard unit
13
Call guard unit when indoor
14
station PIN is required
Control switch actuator
15
Command
[1] [#]
Command
[3] [#]
[2] [#]
[5] [1] [#] to [5] [199] [#]
Command
[1] [1] [#] to [1] [9] [#] or [1] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [1] [1] [#] to [1] [9] [#]
or [*] Indoor station number [*]
Indoor station PIN [*] [1] [#]
[1] [0] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [1] [0] [#]
[3] [1] [#] to [3] [9] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [3] [1] [#] to [3] [9] [#]
[3] [0] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [3] [0] [#]
[2] [1] [#] to [2] [9] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [2] [1] [#] to [2] [9] [#]
[2] [0] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [2] [0] [#]
[4] [#]
[*] Indoor station number [*]
Indoor station PIN [*] [4] [#]
[5] [1] [#] to [5] [199] [#]
Example or explanation
Example or explanation
Open default lock of outdoor station
Open the second lock of outdoor station
Example or explanation
[1] [1] [#] to [1] [9] [#] to call a special
Outdoor station
[1] [#] will call outdoor station 1
— 11 —