26 Actual signals and parameters
All parameters
No.
Name/Value
USER S2
SAVE
USER S3
LOAD
USER S3
SAVE
USER S4
LOAD
USER S4
SAVE
USER S5
LOAD
USER S5
SAVE
USER S6
LOAD
USER S6
SAVE
9907 MOTOR NOM
FREQ
0.0...1400.0 Hz Frequency
9908 MOTOR NOM
SPEED
50...32000 rpm Speed
Description
Save User 2 macro. Stores the current parameter settings
and the motor model.
User 3 macro loaded into use. Before loading, check that
the saved parameter settings and the motor model are
suitable for the application.
Save User 3 macro. Stores the current parameter settings
and the motor model.
User 4 macro loaded into use. Before loading, check that
the saved parameter settings and the motor model are
suitable for the application.
Save User 4 macro. Stores the current parameter settings
and the motor model.
User 5 macro loaded into use. Before loading, check that
the saved parameter settings and the motor model are
suitable for the application.
Save User 5 macro. Stores the current parameter settings
and the motor model.
User 6 macro loaded into use. Before loading, check that
the saved parameter settings and the motor model are
suitable for the application.
Save User 6 macro. Stores the current parameter settings
and the motor model.
Defines the nominal motor frequency, ie the frequency at
which the output voltage equals the motor nominal voltage:
Field weakening point = Nom. frequency · Supply voltage /
Motor nom. voltage
Defines the nominal motor speed. Must be equal to the
value on the motor rating plate.
Def/FbEq
-3
-4
-5
-6
-7
-8
-9
-10
-11
E: 50.0 Hz
U: 60.0 Hz
1 = 0.1 Hz
Type
dependent
1 = 1 rpm