2.4.2

Transport and storage conditions

Originally packaged modules
The following data applies to modules in their original packaging.
Table 2- 4
Function
Temperature range
Relative air
humidity U
Condensation
Temperature change
2.4.3

Environmental conditions

Relevant standards
● Contaminants: Class 3C1 according to EN 62477-1 or IEC 61800-2 draft (referred to
2013).
● It is only permissible to operate the device in rooms/areas with degree of pollution 2
(according to EN 61800-5-1).
● If the HLA module is operated in rooms/areas with levels of dust that could impair the
functionality, it must be operated in a cabinet with a heat exchanger or in a cabinet with a
suitable air intake.
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
Climatic conditions
Remark
Lower temperature limit
Upper temperature limit
No rain, no condensation, no spray water, no for-
mation of ice, no salt mist
Regarding condensation, the following conditions
may apply simultaneously
Max. condensation period
Frequency of condensation
Shortest sequence of condensation cycles
Within one minute
Within one hour
System overview
2.4 System data
Value
-25 °C
+55 °C
5 ... 95 %
Seldom, brief, slight
3 hours
Annual average: 3
Maximum: 10
1 day
0.5 K
30 K