Power Requirements; Table 1-4 Vme Sysreset Enable/Disable (User Configurable) - Switch (S6); Table 1-5 Universe Ii Mapping/Sysfail Generation (User Configurable) - Switch (S7) - GE VMIVME-7805 Hardware Reference Manual

Intel pentium 4 processor m-based vme single board computer
Table of Contents

Advertisement

Table 1-4 VME SYSRESET Enable/Disable (User Configurable) - Switch (S6)

Select
Disable VME SYSRST Driver
Enable VME SYSRST Driver
Disable VME SYSRST Receiver
Enable SYSRST Receiver

Table 1-5 Universe II Mapping/SYSFAIL Generation (User Configurable) - Switch (S7)

Select
Map UNIV2 to Memory Space
Map UNIV2 to I/O Space
Disable SYSFAIL Generation
Enable SYSFAIL Generation

1.3.2 Power Requirements

The VMIVME-7805/VME-7805RC require +5 V from the VME backplane. Below
are the voltage and current requirements.
Supply
Current (Typical)
+5V
6.08A
The VMIVME-7805/VME-7805RC provide power to the PMC site in accordance
with the PMC specification. The maximum current provided on the +5 V supply is
1.5 A per PMC site. The maximum current provided on the +3.3 V supply is 1.5 A
per PMC site.
Switch Position
Open
Closed
Open
Closed
Switch Position
Open
Closed
Open
Closed
Current (Maximum)
8.2A
Switch No.
1 - 4
1 - 4
2 - 3
2 - 3
Switch No.
1-4
1-4
2-3
2-3