Communication PROFIBUS DP/PROFINET IO
10.1 Communication according to PROFIdrive
● Resolution: Encoder pulses ∙ 2n
Figure 10-15 Subdivision and settings for Gx_XIST2
● Encoder lines of incremental encoder
Error code in Gn_XIST2
Table 10- 33 Error code in Gn_XIST2
n_XIST2
Meaning
1
Encoder error
2
Zero mark monitoring
3
Abort parking sensor
4
Abort find reference mark
5
Abort, retrieve reference
value
6
Abort flying measurement •
460
n: fine resolution, no. of bits for internal multiplication
– For encoders with sin/cos 1Vpp:
Encoder lines = no. of sinusoidal signal periods
One or more existing encoder faults.
Detailed information in accordance with drive messages.
Parking drive object already selected.
A fault exists (Gn_ZSW.15 = 1)
Encoder has no zero mark (reference mark)
reference mark 2, 3 or 4 is requested
Switchover to "Flying measurement" during search for reference mark
Command "Read value x" set during search for reference mark
Inconsistent position measured value with distance-coded reference marks.
More than four values requested
No value requested
Requested value not available
No probe configured p0488, p0489
Switch over to "reference mark search" during flying measurement
Command "Read value x" set during flying measurement
110
9
8
Possible causes / description
Function Manual, (FH1), 10/2008, 6SL3097-2AB00-0BP5
Drive functions

Advertisement

Table of Contents
loading

Table of Contents