ABB COM600 Station Automation Series User Manual page 29

Com600 3.2
Hide thumbs Also See for COM600 Station Automation Series:
Table of Contents

Advertisement

1MRS756125
COM600 Station Automation Series
User's Guide
This account is disabled by default for security reasons. You
can enable it temporarily during the configuration phase to
enable access to the COM600 computer if the COM600
password is lost. It is recommended that you disable the
Administrator account later when the COM600 computer is
connected to the actual network.
Username: COM600
Password: aEc2006rs
This is the main account of the COM600 computer. It is used for configuration purposes.
Processes of the COM600 computer are run under this account.
Connecting configuration computer with CET to COM600 computer
1. Configure the network settings of the configuration computer and the COM600
computer to allow them to communicate with each other. This is done by configuring
the IP addresses of the computers into the same subnetwork. Configure (or disable)
the possible firewall in the configuration computer to pass DCOM.
2. Connect either a crossover LAN cable between the computers or connect both
computers to a network switch. Use the LAN port used for local use in COM600
computer.
3. Create a COM600 user account with administrator rights to the configuration com-
puter. The password must be the same as in the COM600 computer.
4. Log in to the configuration computer as a COM600 user and launch CET.
5. Create a project and add the Gateway object to the communication structure.
6. Type the IP address of the COM600 computer LAN port used for configuration to
the IP address property of the Gateway object.
7. Right-click the Gateway object and select Management. Verify that the communic-
ation with the COM600 computer is working properly. The first time you open the
management tool, you are required to change the COM600 user password. Click
Change password to change the password both in the COM600 computer and in
the configuration computer.
You have to close CET and log in to windows to activate the new password.
The COM600 user password must always be changed as described above to ensure
that the password is changed correctly for each component in the COM600 computer.
If you lose the password you will not be able to access the
COM600 computer anymore either locally or remotely.
If you want to run CET using a different user account than COM600 in the configuration
computer, you must do the following. If you use the COM600 user, you can skip the
phases below.