Configure a G-240W-C indoor ONT
3
4
Procedure 12
1
Figure 25
Table 21
(1 of 2)
76
R05.05.01 | December 2016 | 3FE 46690 AAAA TCZZA | Edition 01
Click Refresh to update the displayed information.
STOP. This procedure is complete.
Optics module status retrieval
Select Status > Optics Module Status from the top-level menu in the GPON Home Gateway
window, as shown in Figure 25.
Optics module status window
Table
21
describes the fields in the Optics module status window.
Optics module status parameters
Field
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics Module Temperature (ONT ANI-ONT-Side Optical
Measurements)
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)
Lower (ONT ANI-ONT-Side Optical Measurements-Optical
Threshold)
7368 ISAM ONT G-240W-C Product Guide
Description
Laser bias current, measured in uA
Optics module voltage, measured in V
Optics module temperature, measured in C
Received optics signal level at 1490 nm,
measured in dBm
Transmitted optics signal level at 1310 nm,
measured in dBm
Lower optical threshold, measured in dBm