Emergency Stopping - Beta Marine Beta 14 Installation Manual

Heat exchanger cooled
Table of Contents

Advertisement

EMERGENCY STOPPING

Every propulsion engine is fitted with a back up stop lever.
To activate and stop the engine manually, simply press
the stop lever highlighted in image 45 down and hold in
place until engine stops.
For control panels operated by a key switch, turn the
key from the run to the off position. Then for all engines
regardless of control panel type, isolate the starter battery.
45
Speed Lever
Stop Lever
The emergency engine stop lever is located:
All variants (excluding Beta 75, 90, 90T, 105T & 115T)
Forward end, mid level, starboard side when viewed from
the gearbox end.
When leaving the vessel for an extended period: turn off the sea-cock if heat exchanger cooled and isolate
the starter battery.
WARNING!
DO NOT leave the key in the 'OFF' position when
engine is running. This will not allow the alternator
to charge and will damage the alternator.
DO NOT depress the stop lever for more than ten
seconds as this will lead to overheating and failure
of the solenoid.
Beta 75, 90, 90T, 105T & 115T
Mid engine, mid level, starboard side when viewed from
the gearbox end.