Error code
Error message
Invalid RAID
2842
Invalid Size
2843
Invalid Stripe Size
2844
Invalid ClearConfigurationWithDataLoss
2849
parameter
Controller does not support Chassis Name
2850
Invalid Chassis Name
2851
Invalid SSP State
2852
Cannot change SSP settings
2853
Invalid SSP Adapter ID
2854
Invalid Surface Scan Delay
2857
Controller does not support redundancy
2861
settings
Invalid Preferred Path Mode
2864
Invalid Preferred Path
2865
Failure opening capture file
2866
Failure opening input file
2867
Failure opening error file
2868
There are no suitable spares available
2877
Invalid Physical Disk Type Specified
2880
Invalid MNP delay
2882
Invalid Cache Logical Drive
2883
Invalid Caching Array
2884
Error creating Caching Logical Drive
2885
Error creating Caching Array
2886
Error modifying Caching Volume
2887
Unable to modify Caching Arrays
2888
The requested Array modification is invalid
2889
Comment or clarification
has no free space.
The specified RAID level is invalid or is not possible
with the current physical disk and array
configuration.
The specified size is invalid or is not possible with
the current configuration.
The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the
current configuration.
The valid parameters are Yes and No (default).
The controller does not support setting a chassis
name.
The entered chassis name is invalid. Use characters
from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _,
+, :, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
The requested SSP state is not a valid SSP state.
The SSP settings cannot be changed for the
controller or logical drive.
The adapter ID is not a valid adapter ID that was
detected by the controller.
The controller is not redundant or does not support
redundancy settings.
The specified value for the preferred path mode is
not valid, or the controller is not available.
The specified preferred path is not a valid chassis
slot for an available, active controller, or the
controller is not available.
SSA found no drives that could be used as spares for
the specified array.
The specified value for MNP delay is invalid.
The specified caching logical drive ID is invalid.
The specified caching array ID is invalid.
Caching arrays cannot be modified once created.
Error specifying the list of drives when reconfiguring
an array