SSA scripting warning messages

Warning
Warning message
code
License key is already installed
4000
Clear configuration command failed -
4001
configuration is already cleared
Chassis name is already set to this value
4002
One or more controller commands were
4003
skipped because the controller is not
configured
Using Repeat function
4004
The system must be rebooted for the
4005
firmware flash to complete
Unable to set the array accelerator for this
4006
volume. The cache board may be missing or
have a bad status, or the controller may not
support a cache
The controller does not have a battery
4007
attached
The controller battery status is Failed
4008
This parameter cannot be modified
4009
Rapid Parity Initialization is not available
4010
The command is not available when
4011
MODE=CONFIG
The command is not availbale when
4012
MODE=RECONFIG

SSA scripting error messages

Error code
Error message
0
Too many coinciding expansion, migration,
2053
or extension operations
Controller does not support license keys
2056
Invalid license key
2059
Controller does not support SSP
2064
Invalid Action
2817
Invalid Method
2818
Invalid Controller
2819
No controllers detected
2821
Comment or clarification
The input file specified a license key. However, a
license key is already installed on the controller.
The -reset option was used on a controller that
does not have a configuration.
The chassis name is already set to the supplied
value. The command is ignored.
Certain commands require that the controller be
configured before they can be sent to the
controller.
Some commands have been ignored because the
Repeat parameter has been specified in the input
file.
A controller has been flashed with new firmware.
The new firmware requires a reboot to take effect.
The controller may not support a cache (for
example, some Software RAID controllers) or the
cache may be missing or defective.
The operation requested requires a battery and one
was not attached.
The operation requires a battery and the attached
battery has failed.
The input script attempted to modify a parameter
which is not modifiable.
Rapid Parity Initialization is not available on the
selected volume; there may already be an RPI in
progress, or the firmware does not support RPI.
Comment or clarification
No error exists. The program completed successfully.
The new configuration requires more
transformations than are possible at one time. For
example, you cannot expand a logical volume and
transform its RAID level at the same time.
The controller does not support license key entry or
deletion.
The entered license key is not a valid license key.
The controller does not support SSP functions.
The requested actions are invalid, for example,
combining -reset with capture mode.
The method must be either Custom or Auto.
An invalid controller value was specified.
No controllers were detected. This error applies to
SSA Scripting 91