Cycle communication using PROFINET IO with IRT or using RT is possible on all drive units
equipped with a PROFINET interface. This means that problem-free communication using
other standard protocols is guaranteed within the same network.
Note
PROFINET for drive technology is standardized and described in the following document:
PROFIBUS profile PROFIdrive - Profile Drive Technology
Version V4.1, May 2006,
PROFIBUS User Organization e. V.
Haid-und-Neu-Straße 7,
D-76131 Karlsruhe
http://www.profibus.com,
Order no. 3.172, spec. Chapter 6
• IEC 61800-7
CAUTION
For CU320-2 DP with inserted CBE20, the cyclic PZD channel for PROFIBUS DP is
deactivated. When setting parameter p8839 = 1, the PZD channel can be reactivated (see
Chapter "Parallel operation of communication interfaces").
10.3.1.1

Real-time (RT) and isochronous real-time (IRT) communication

Real-time communication
When communication takes place via TCP/IP, the resultant transmission times may be too
long and non-deterministic to meet production automation requirements. When
communicating time-critical IO user data, PROFINET IO therefore uses its own real-time
channel, rather than TCP/IP.
Determinism
Determinism means that a system will react in a predictable ("deterministic") manner.
With PROFINET IO, it is possible to precisely determine (predict) transmission times.
PROFINET IO with RT (Real Time)
Real time means that a system processes external events over a defined period.
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
10.3 Communication via PROFINET IO
Communication
629