b) I/O DISPLAY
The status of each sensor and switch is shown in the display.
Sensor and switch status is shown in the display.
ON = 1
OFF or not used = 0
Screen 1
Screen 2
Screen 1 and Screen 2 are selectable with the
These screens display the associated sensor status as listed in the table below.
Display
position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
I
/
O
D I S P L A Y
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1
2
3
4
5
6
7
8
I
/
O
D I S P L A Y
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
and
keys.
Sensor name
Pump Cam Sensor
Valve Open/Closed Detection Sensor
(Not Used)
(Not Used)
Spur Cam Sensor
Lift Cam Sensor
Feed Roller HP Sensor
Top Cover Sensor
(Not Used)
Ink Tank Cover Switch
(Not Used)
Paper Detection Sensor
(Not Used)
(Not Used)
(Not Used)
(Not Used)
Roll Media Sensor
Roll Cam Sensor
Cutter Lift Sensor
Cutter Right Position Sensor
Cutter HP Sensor
(Not Used)
(Not Used)
(Not Used)
(Not Used)
Roll unit detection
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
1
9 10 11 12 13 14 15 16
F-7-6
2
F-7-7
T-7-118
LCD display contents
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
-
-
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
0:Cover open, 1:Cover close
-
0:Cover open, 1:Cover close
-
0:Sensor ON, 1:Sensor OFF
-
-
-
-
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
0:Sensor ON, 1:Sensor OFF
-
-
-
-
0:Roll unit not detected, 1:Roll unit detected
-
-
-
-
-
-
(Upper row)
(Lower row)
(Display position)
(Upper row)
(Lower row)
(Display position)
Chapter 7
7-61