COMMAND 135: WRITE CALIBRATION LOCATION
Command-Specific Response Code
7
In Write Protect Mode
The Write protect link on the transmitter is "on"
12 Invalid Calibration Location code
14 Warning: Default values set for User calibration
This message is made the first time the user
calibration is selected
COMMAND 136: READ LAST TRIM POINT VALUES
Command-Specific Response Code
10 Error: Calibration Location not set to User
The trim point values can be read only if the User
location has been selected
COMMAND 137: READ TRIM VARIABLE VALUE
Command-Specific Response Code
3
Applied input too large
4
Applied input too small
The input applied during a sensor trimming
operation exceed the sensor limits
COMMAND 138: WRITE STATIC DATA - OPTIONS
Command-Specific Response Code
7
In Write Protect Mode
The Write protect link on the transmitter is "on"
13 Invalid Meter Option

DATA BASE OPERATIONS MESSAGES

NO TAGS IN DATABASE

No configurations stored in the Communicator Databa-
se memory.
TAG IS NOT IN HT
The selected Tag is not included in the Communicator
Tag list : no configuration is saved for this Tag.
TAG ALREADY EXIST
A configuration with the same Tag has already been
saved in the Communicator Database memory.
DATABASE MEMORY FULL
No more space available in the Communicator Databa-
se memory.
INCOMPATIBLE MANUFACTURER
Attempt to load a configuration in a device of a different
manufacturer.
INCOMPATIBLE DEVICE
Attempt to load a configuration in a device incompatible
with that configuration.