Chapter 6
Monitoring Settings
6.6
Transmission Test Execution
(6)
Check the test transmission completion message and click the [Done] button.
The screen display returns to the [Network] screen.
2
Check the result of the test transmission.
Check that the SNMP Trap is notified to the monitoring server.
For details on the messages for test transmission, refer to "Message List".
If the SNMP Manager cannot receive an SNMP test trap, check that the network has no trouble, and the
settings for the ETERNUS AF are correct.
Is the LAN between the monitoring server and ETERNUS AF connected correctly?
•
Execute the "ping" command from the monitoring server, and confirm the reply from the ETERNUS AF.
When "ICMP" is disabled by the firewall settings for ETERNUS Web GUI, the "ping" command cannot
be used for confirmation. Enable "ICMP" before executing the "ping" command.
Is the monitoring software set correctly to monitor the ETERNUS AF?
•
Are the SNMP environment settings and the transmission destination for the SNMP Trap set correctly
•
on the ETERNUS AF?
6.6.2
Send Test E-mail
Perform an e-mail transmission test to check that the e-mail can be sent from the ETERNUS AF to the speci-
fied e-mail address.
The procedure to send a test e-mail is as follows:
1
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2
In [Category], click [Network].
The [Network] screen appears.
3
In [Action], click [Setup E-Mail Notification].
The [Setup E-Mail Notification] screen appears.
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
103