REV0
10.02.15
Take the reverse step for assembly
8.3.40 Replacing the F/L Sensor
#105 F/L Bracket ASSY
Bind-head screw
#105 F/L Bracket ASSY
F/L Sensor Connector
#105 F/L Bracket ASSY
F/L Sensor Hook
-H8-52-
Pick(U)Cover
F/L Sensor Cable
F/L Sensor
#58 F/L Sensor
F/L Sensor Cable
F/L Sensoe Hook
Plate(FL)
Screw
Caution: Make sure to attach the Sensor properly.
It may be the cause of errors
Tools Needed: Magnetic Philips Screwdriver (No.2)
① Remove the Pick Unit ASSY and the Pick (U)
Cover.
② Unscrew 2 bind-head screws on the F/L Bracket
ASSY and remove the F/L Bracket
※ Do not pull hard to remove the F/L Bracket
ASSY. The F/L Sensor Cable is routed onto the
F/L Bracket ASSY.
③ Disconnect the connector from the F/L Sensor
Cable.
④ Unscrew 1 screw from the countersunk (FL) and
remove the F/L Sensor.
⑤ Take the reverse steps to attach the F/L Sensor
#58 F/L Sensor
(Photo Micro
Sensor ASSY)