Table B–9: MODBUS MEMORY MAP (Sheet 2 of 41)
ADDR
REGISTER NAME
041C
...Repeated for module number 29
041D
...Repeated for module number 30
041E
...Repeated for module number 31
041F
...Repeated for module number 32
Digital Counter States (Read Only Non-Volatile) (8 modules)
0800
Digital Counter 1 Value
0802
Digital Counter 1 Frozen
0804
Digital Counter 1 Frozen Time Stamp
0806
Digital Counter 1 Frozen Time Stamp us
0808
...Repeated for module number 2
0810
...Repeated for module number 3
0818
...Repeated for module number 4
0820
...Repeated for module number 5
0828
...Repeated for module number 6
0830
...Repeated for module number 7
0838
...Repeated for module number 8
FlexStates (Read Only)
0900
FlexState Bits (16 items)
Element States (Read Only)
1000
Element Operate States (64 items)
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
Element Targets (Read Only)
14C0
Target Sequence
14C1
Number of Targets
Element Targets (Read/Write)
14C2
Target to Read
Element Targets (Read Only)
14C3
Target Message
Digital I/O States (Read Only)
1500
Contact Input States (6 items)
1508
Virtual Input States (2 items)
1510
Contact Output States (4 items)
1518
Contact Output Current States (4 items)
1520
Contact Output Voltage States (4 items)
1528
Virtual Output States (4 items)
1530
Contact Output Detectors (4 items)
Remote Input/Output States (Read Only)
1540
Remote Device 1 States
1542
Remote Input States (4 items)
1550
Remote Devices Online
Remote Device Status (Read Only) (16 modules)
1551
Remote Device 1 StNum
1553
Remote Device 1 SqNum
1555
...Repeated for module number 2
1559
...Repeated for module number 3
155D
...Repeated for module number 4
1561
...Repeated for module number 5
1565
...Repeated for module number 6
1569
...Repeated for module number 7
156D
...Repeated for module number 8
GE Multilin
RANGE
-2147483647 to
2147483647
-2147483647 to
2147483647
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 65535
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 4294967295
0 to 4294967295
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F004
---
1
F004
---
1
F050
---
1
F003
---
1
F001
---
1
F502
---
---
F200
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F200
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F126
---
1
F003
---
1
F003
DEFAULT
B
0
0
0
0
0
0
(none)
0
0
0
0
"."
0
0
0
0
0
0
0
0
0
0 (No)
0
0
B-9

Advertisement

Table of Contents
loading

Table of Contents